Issue 17257: Figure 9.7 (sysml-rtf) Source: No Magic, Inc. (Mr. Nerijus Jankevicius, nerijus(at)nomagic.com) Nature: Uncategorized Issue Severity: Summary: reference properties "sp" in all subtypes must redefine "sp" from block P. also, p1, p2, p3 in Plug Design 1 - are they redefining or not? if yes, must be {redefines} used, if not, how <<proxy>> appears there? Resolution: Revised Text: Actions taken: March 20, 2012: received issue Discussion: End of Annotations:===== s is issue # 17257 From: Nerijus Jankevicius Figure 9.7 reference properties "sp" in all subtypes must redefine "sp" from block P. also, p1, p2, p3 in Plug Design 1 - are they redefining or not? if yes, must be {redefines} used, if not, how <> appears there? From: "Watson, John" To: "conrad.bock@nist.gov" , "sysml-rtf@omg.org" CC: "Watson, John" Subject: SysML RTF 1.4, Ballot 3, Issue # 17257 Thread-Topic: SysML RTF 1.4, Ballot 3, Issue # 17257 Thread-Index: Ac3HXlseD6OcXKHMQ6OqTnzAYhsvTw== Date: Tue, 20 Nov 2012 20:33:58 +0000 Accept-Language: en-US X-MS-Has-Attach: X-MS-TNEF-Correlator: x-originating-ip: [158.186.156.93] X-Proofpoint-Virus-Version: vendor=fsecure engine=2.50.10432:5.9.8185,1.0.431,0.0.0000 definitions=2012-11-20_04:2012-11-20,2012-11-20,1970-01-01 signatures=0 Conrad, On issues # 17257 there is a typo on the replacement figure. On the block .Plug Design 1. the each of the 3 ports (p1, p2 and p3) indicates it .redefines p1.. The text on each of the ports should be .refines p1., .redefines p2. and .redefines p3., respectively. A similar issue exists on the block .Plug Design 2. on ports p2 and p3. John ======================== John C. Watson PMES, CE&T System Modeling CoE Lead Lockheed Martin MS2 199 Borton Landing Road MS 137-106 Moorestown, NJ 08057 Office: 856-722-2783 Links To: CE&T MBSD Integrated Website System Modeling CoE Homepage INCOSE MBSE Initiative Wiki From: "BERNARD, Yves" To: "Watson, John" , "conrad.bock@nist.gov" , "sysml-rtf@omg.org" Date: Wed, 21 Nov 2012 07:10:54 +0100 Subject: RE: SysML RTF 1.4, Ballot 3, Issue # 17257 Thread-Topic: SysML RTF 1.4, Ballot 3, Issue # 17257 Thread-Index: Ac3HXlseD6OcXKHMQ6OqTnzAYhsvTwAUDhWA Accept-Language: fr-FR, en-US X-MS-Has-Attach: X-MS-TNEF-Correlator: acceptlanguage: fr-FR, en-US John, Good catch! I missed it. I assume you mean .redefines. and not .refines. for Plug Design1::p1 Yves From: Watson, John [mailto:john.watson@lmco.com] Sent: mardi 20 novembre 2012 21:34 To: conrad.bock@nist.gov; sysml-rtf@omg.org Cc: Watson, John Subject: SysML RTF 1.4, Ballot 3, Issue # 17257 Conrad, On issues # 17257 there is a typo on the replacement figure. On the block .Plug Design 1. the each of the 3 ports (p1, p2 and p3) indicates it .redefines p1.. The text on each of the ports should be .refines p1., .redefines p2. and .redefines p3., respectively. A similar issue exists on the block .Plug Design 2. on ports p2 and p3. John ======================== John C. Watson PMES, CE&T System Modeling CoE Lead Lockheed Martin MS2 199 Borton Landing Road MS 137-106 Moorestown, NJ 08057 Office: 856-722-2783 Links To: CE&T MBSD Integrated Website System Modeling CoE Homepage INCOSE MBSE Initiative Wiki The information in this e-mail is confidential. The contents may not be disclosed or used by anyone other than the addressee. Access to this e-mail by anyone else is unauthorised. If you are not the intended recipient, please notify Airbus immediately and delete this e-mail. Airbus cannot accept any responsibility for the accuracy or completeness of this e-mail as it has been sent over public networks. If you have any concerns over the content of this message or its Accuracy or Integrity, please contact Airbus immediately. All outgoing e-mails from Airbus are checked using regularly updated virus scanning software but you should take whatever measures you deem to be appropriate to ensure that this message and any attachments are virus free.