Issue 18002: Location: p. 337 Conflicting Transitions (uml25-ftf) Source: International Business Machines (Mr. Omar Badreddin, oobahy(at)gmail.com) Nature: Clarification Severity: Minor Summary: Clarification of conflicting transitions This requires clarification. So, does this mean that conflicting transitions are not allowed? Sometimes conflicting transitions can only be identified at run time, for example, in the case of guarded transitions. The following paragraph clarifies some of the ambiguity, but not all of it. Still, the case when two transitions are at the same nesting level is still ambiguous. Resolution: Revised Text: Actions taken: September 27, 2012: received issue Discussion: End of Annotations:===== s is issue # 18002 Problem: 14.058 Severity: Minor Type: Clarification Location: p. 337 Conflicting Transitions Title: Clarification of conflicting transitions This requires clarification. So, does this mean that conflicting transitions are not allowed? Sometimes conflicting transitions can only be identified at run time, for example, in the case of guarded transitions. The following paragraph clarifies some of the ambiguity, but not all of it. Still, the case when two transitions are at the same nesting level is still ambiguous. Source: Omar Bahy Badreddin