Issue 19413: bug issue concerning event-based gateway (bpmn2-rtf) Source: (, ) Nature: Uncategorized Issue Severity: Summary: I read BPMN 2.0.2 specification and I found a mistake on a table (I think): P329 of PDF or p299 of BPMN specification : The attribute can only be set to parallel when the instantiate attribute is set to true. I assume its wrong. A better sentence would be : The attribute can only be set to parallel when the instantiate attribute is set to false. Am I correct ? Resolution: Revised Text: Actions taken: May 13, 2014: received issue Discussion: End of Annotations:===== iler: QUALCOMM Windows Eudora Version 7.1.0.9 Date: Tue, 13 May 2014 11:15:46 -0400 To: "issues@omg.org" , bpmn2-rtf@omg.org From: Juergen Boldt Subject: issue 19413 -- BPMN 2 RTF X-Virus-Scanned: amavisd-new at omg.org X-Gm-Message-State: ALoCoQnFrOfS3A99EPdbnPK2FDpzrjejs9LpW9QWPlLE264rj56M/Ld2SfLnaMMovrxQWaZeW57A X-Received: by 10.224.21.1 with SMTP id h1mr11378304qab.103.1399965564513; Tue, 13 May 2014 00:19:24 -0700 (PDT) From: Julien Perdriel X-Mailer: Microsoft Office Outlook 12.0 Thread-Index: Ac9eCke0VHz/QEJ9SbWlVRkxvm7u9QQcMrcw Date: Tue, 13 May 2014 09:19:24 +0200 Subject: [BPMN 2.0.2] bug issue concerning event-based gateway To: juergen@omg.org X-Virus-Scanned: amavisd-new at omg.org Hello Juergen,  I read BPMN 2.0.2 specification and I found a mistake on a table (I think): P329 of PDF or p299 of BPMN specification : “The attribute can only be set to parallel when the instantiate attribute is set to true.”  I assume it’s wrong. A better sentence would be : “The attribute can only be set to parallel when the instantiate attribute is set to false.”  Am I correct ?  Let me know, Julien PERDRIEL Portable : 06 32 555 808 [] arismore - www.arismore.fr 137 Bureaux de la Colline - 92213 Saint-Cloud Cedex - France []   De : Julien Perdriel [ mailto:julien.perdriel@arismore.fr] Envoyé : mardi 22 avril 2014 11:07 À : 'juergen@omg.org' Objet : [BPMN 2.0.2] bug issue concerning event sub process  Hello Juergen,  I read BPMN 2.0.2 specification and I found a mistake on an illustration (I think): p174 (205 of PDF)  : “If the Event Sub-Process is collapsed, then its Start Event will be used as a marker in the upper left corner of the shape (see Figure 10.30).” P175 There is no marker in the upper left corner of the collapsed event sub-process.  Have a nice day, Julien PERDRIEL http://www.arismore.fr/logo_arismore.png arismore - www.arismore.fr 137 Bureaux de la Colline - 92213 Saint-Cloud Cedex - France Ligne directe : 01 74 71 04 80 - Portable : 06 32 55 58 08 Standard : 01 55 57 21 60 - Fax : 01 55 57 04 45 Juergen Boldt Director, Member Services 109 Highland Ave Needham, MA 02494 USA Tel: +1 (781) 444 0404 x 132 fax: +1 (781) 444 0320 www.omg.org []