Issue 4812: Issue surveillance FTF: Last measured Mode C (surveillance-ftf) Source: THALES (Mr. Emmanuel Fuchs, elfuchs@club-internet.fr omg@elfuchs.com) Nature: Uncategorized Issue Severity: Summary: A new issue for surveillance manager FTF. In order to support Short Term Conflict Alert the track informatioin need Last measured Mode C. Proposed solution : Addition of I030/140 - Last measured Mode C Resolution: Addition of I030/140 - Last measured Mode C Revised Text: Page 3.2 insert a new line in the data item table. Page 3.6 insert I30/140 : LAST MEASURED MODE C Definition : Mode C code of the last nearest neighbour plot containing a Mode C and used to update the track. typedef boolean Is_valid_Mode_C_code; typedef boolean Is_garbled_information; struct LastMesuredModeC { boolean Is_valid_Mode_C_code; boolean Is_garbled_information; Feet Mode_C }; in 3.2.1.11 I30 Track insert the field LastMesuredModeC last_mesured_mode_C; // I030/140 Issue 4812 In 4, change IDL source Actions taken: January 22, 2002: received issue February 14, 2003: closed issue Discussion: End of Annotations:===== Date: Tue, 22 Jan 2002 16:34:54 +0100 From: Emmanuel FUCHS Organization: Thales ATM X-Mailer: Mozilla 4.75 [fr] (WinNT; U) X-Accept-Language: fr MIME-Version: 1.0 To: Juergen Boldt , FTF surveillance Subject: Issue surveillance FTF: Last measured Mode C Content-Transfer-Encoding: 7bit Content-Type: text/plain; charset=us-ascii X-UIDL: ]=A!!F;c!!/>R!!:`Yd9 Hi Jurgen A new issue for surveillance manager FTF. In order to support Short Term Conflict Alert the track informatioin need Last measured Mode C. Proposed solution : Addition of I030/140 - Last measured Mode C Best regards Emmanuel FUCHS