Issue 5564: Compliance point issues (smart-transducers-ftf) Source: (, ) Nature: Revision Severity: Summary: At the OMG Technical Meeting in Dublin the following things have been identified by the AB as subject for revision: 1. Delete Sec. 3.3 2. List Sec. 3.1.1 and 3.2.1 as single mandatory compliance points. 3. Identify List of Functions in Secs. 3.1.2 and 3.2.2 as individual, optional compliance points Resolution: Accept changes as proposed. Revised Text: 9/29/02 Page 6 Section 3.3 has been deleted. The former sections "3.1 Mandatory versus Optional Requirements for Smart Transducers (ST)" and "3.2 Mandatory versus Optional Interfaces at the CORBA Gateway" and all subsections have been rearranged to "3.1 Mandatory Requirements" and "3.2 Optional Requirements" (without the need for subsections): 3.1 Mandatory Requirements Every ST must support MS rounds in order that one can read the physical name of an ST from the CORBA interface. This function is necessary to learn about the existence of an ST in a cluster. Every ST must support at least reading of the first, second, and third (0x00, 0x01, and 0x02) record of the documentation file 0x3D as described in Section 2.4.6, “The Documentation File (file no. 0x3D),” on page 2-19 in order to allow reading the physical name. Smart Transducers FTF Finalization Task Force Report Disposition: Accepted OMG Issue No: 5564 9/29/02 Page 7 Every master must provide the capability to translate the representation of the internal time of its cluster to the representation of the external time. Every CORBA gateway must provide the three interfaces: the RS interface, the DM interface, and the CP interface. 3.2 Optional Requirements In addition to the mandatory services an ST compliant to this specification may support an arbitrary set of the following optional services: • Fixed MP Round A low-cost ST that is used in mass-market applications may contain only one or more a-priori preprogrammed RODLs in its ROM memory. Other low-cost nodes may not support any MP round. • Programmable MP Round This function makes it possible to change the RODL within an ST on-line. • Baptizing of STs without an assigned Logical Name This function enables the on-line assignment of a logical name to an ST that has no a-priori assigned logical name (the logical name 0xFF denotes an ST currently not integrated in the system). • Identification of STs (Plug and Play) This function enables the on-line identification of a new node that has been detected to exist. • Sleep and Wakeup Service This function enables a cluster to enter the sleep mode and to wake-up the cluster after a significant event has occurred. • First Membership This function provides membership information about STs that participate in MP rounds. • Second Membership This function provides membership information about currently available STs in a cluster. • External Clock Synchronization at Master or CORBA Gateway Smart Transducers FTF Finalization Task Force Report Disposition: Accepted OMG Issue No: 5565 The master or the CORBA gateway may provide an external clock synchronization interface in order to synchronize the actions of the master with an external time reference (e.g., GPS). Actions taken: August 5, 2002: received issue December 11, 2002: closed issue Discussion: End of Annotations:===== ISSUE #xx (author: AB) TYPE: Minor Change At the OMG Technical Meeting in Dublin the following things have been identified by the AB as subject for revision: 1. Delete Sec. 3.3 2. List Sec. 3.1.1 and 3.2.1 as single mandatory compliance points. 3. Identify List of Functions in Secs. 3.1.2 and 3.2.2 as individual, optional compliance points ACTION Section 3.3 has been deleted. The former sections "3.1 Mandatory versus Optional Requirements for Smart Transducers (ST)" and "3.2 Mandatory versus Optional Interfaces at the CORBA Gateway" and all subsections have been rearranged to "3.1 Mandatory Requirements" and "3.2 Optional Requirements" (without the need for subsections).